Add to Cart
Fire Protection Intumescent Finishing Wood Fire Resistant Coating
It integrated decorative effect with fireproof function. When the coating suffering fire attack, it can be expanded and form a uniform honeycomb layer, which can effectively delay the spread speed of fire,
so endeavour to gain more valuable time for fire fighting.Its main components are film-forming emulsion, phosphorus-nitrogen-carbon flame retardant materials, pigments and fillers, additives,etc. it has significant fireproofing effect, stable performance and the paint color can be customized.
Mainly Features:
Product Parameter:
Product Color | White(Support color customization) |
Fireproof rating | More than 15mins when film thickness is 0.3mm |
Construction Usage | 2 ~ 3 ㎡ / kg |
Surface Drying Time | 15 ~ 30 min |
Hard Drying Time | 2.5 ~ 3 hrs |
Termite Proof | YES |
Mildew Proof | YES |
Water Proof | NO |
PH | 7-8 |
Consturction Ambient Temperature | Between 5ºC (41ºF) and 30ºC (86ºF) |
VOC | / |
Shelf Time | 6 months |
Application Method | Brush/spray/roller |
Intended Uses:
Widely used for industrial and civil architecture, high-rise building, landscapes, hotels, theaters, temples, cultural and entertainment venues, ancient buildings of wood materials, fiberboard, particle board, etc.,but not for metal surfaces.
Notes:
Requirement | Moisture content of base material should be 8%-13% |
Surface Preparation | The substrate surface must be clean,dry and free from contamination, such as dust,oil stain,water stain,etc. |
Mixing | This is one component, but need to stir evenly before application |
Construction Method | The construction method could be spray, brush, roller. the spray method is recommended if the constrution area is large,the airbrush caliber is 1.5-2mm.each painting thickness shall be 0.05mm-0.10mm, total painting times depends on the requirement. each painting interval time should be 2-4 hours |
Brush Tool | Wool brush or nylon brush |
Construction Condition | Dont execute construction when temprature is under 5℃ or air humidity is above 80%. maintain good ventilation |
Notes | Materials is not allowed to remain in hoses, guns or spray equipment. All unused materials should be sealed and, clean all tools timely after using with clean water. It is good to periodically flush the spray tools during the daily work.All surplus materials&empty containers should be properly disposed. |
Barrel,
25kg/barrel.
How/Where to Use
What Are The Most Common Applications For Zhuoan’s Fireproof Coating?
The most common applications for Zhuoan’s Fireproof Coating are in the building industry. Historic architecture,wood cottage, furniture,lumber, OSB, polywood, wood fire resistant coating top the list. Hotel, hospital, theater, school ,airport, mall, factory are also a common usage with steel fire resistant coating.
Can Zhuoan’s Fireproof Coating Be Applied Over Existing Rust And Corrosion?
With wood Fireproof Coating,the substrate surface must be clean,dry and free from contamination, such as dust,oil stain,water stain,etc.With steel Fireproof Coating, only a NACE 3 / SSPC-SP 6 commercial blast cleaning is typically necessary.
Application and Training
What Does The Preparation Process Entail?
Only a NACE 3 / SSPC-SP 6 commercial blast cleaning is typically necessary. There is no need to blast to NACE 1 or 2 since slight oxidation on the surface allows for the best chemical reaction.
Can The Speed Of Reaction Be Slowed Down To Increase Working Time Before It Is Cured?
There are various ways to decrease reaction time, but they are specific to the material being coated and environmental factors. We will advise you on this during the consultation.
What Thickness Is Recommended?
For wood Fireproof Coating,11.81mils; for steel Fireproof Coating, 118.11~1968.5mils, specific to the material being coated and fire resistant standard.
Do I Need Special Equipment In Order To Apply Zhuoan’s Fireproof Coatings?
Zhuoan’s fireproof coating applied using a plural (2K) spray gun or brush or roller. For spray model, the coating uses specific ratio, and sprays on using standard plural spray equipment that mixes at the nozzle of the spray gun. The process requires no heating equipment or other apparatus besides the plural spray gun.
What Does The Certification Process Entail?
Training is at our facility or yours. We teach you how to use it, the application process, and how to recognize proper effect. Experienced painters generally pick up the technique and understand the minor differences in a few minutes. We recommend two days of training to allow ample time to cover maintenance of the equipment, trouble shooting, and to understand the technology.
Who Can Apply Zhuoan’s Fireproof Coatings?
Zhuoan’s Fireproof Coatings can be applied by either:
• An Zhuoan’s Fireproof Coatings certified contractor
• Product manufacturers who have been trained by Zhuoan
If Overspray Happens On Adjacent Surfaces Can It Be Easily Removed?
Zhuoan’s Fireproof Coatings can only be removed by sandblast or grit media. Our training team will educate your staff on the process to minimize overspray.
Purchasing Zhuoan’s Fireproof Coatings
There may be an Zhuoan’s Fireproof Coatings distributor near you.
If you are unable to find a distributor or certified applicator near you, please contact us so that we can arrange direct shipment to you.
How Do I Buy Fireproof Coatings?
Zhuoan’s Fireproof Coatings can be purchased through an Zhuoan distributor or by contacting us directly.